What it means
With E21 the control board found the thermal sensor circuit open. JennAir lists the sensor, the board or the wiring between them. Switch the microwave breaker off for a minute and back on.
JennAir microwave E21 / Sensors
With E21 the control board found the thermal sensor circuit open. JennAir lists the sensor, the board or the wiring between them. Switch the microwave breaker off for a minute and back on.
Also shown as E21
With E21 the control board found the thermal sensor circuit open. JennAir lists the sensor, the board or the wiring between them. Switch the microwave breaker off for a minute and back on.
Leave it off for a full minute.
E21 returns after the reset.
Checks you have ticked / saved in this browser

Leave it off for a full minute.

Give it a minute to see whether E21 returns.

Run a short test cycle.

Was the microwave moved, was there a power cut, or had you just cooked a long cycle?
Send the model and the checks you have already run, then begin your request from this page.
Book a visit


A simplified drawing, because layouts change with the model. Tap an outlined part to see a photo and the related check.
The control board found the thermal sensor circuit open.
Read the supporting manualThe sensor, the board, or the wiring that links them.
Read the supporting manualTurn the microwave breaker off, wait a minute, switch it on again and watch the display during the next minute.
Read the supporting manualIf E21 repeats after a reset. An open sensor circuit does not heal on its own.
Read the supporting manualManufacturer document
JennAir Product Help (producthelp.jennair.com)
dateModified 2021-04-27; PH 9584 / PH 9584 (over-the-range microwave)
Scope: JennAir over-the-range microwave. Read from the JennAir Product Help page for this code in the over-the-range microwave error code tree (November 2026).
JennAir describes the circuit as open, meaning the board saw a break in the sensor path.
The sensor, the board, and the wiring that links them.
No. E24 describes an overheat condition of 500 F (260 C). E21 describes an open sensor circuit.
After the reset, test briefly. If E21 repeats, stop and book a visit.
Code or symptom, part, service call
With E24 the cavity registered an overheat reading of 500 F (260 C). JennAir lists the thermal sensor, the gas sensor, the board or the wiring. Turn the microwave breaker off for a minute and on again.
First confirm the controls: enter Cook Time, then Cook Power if it is not 100%, and press Start. Then test with one cup of water for one minute on HI. If heat rise is detected, the microwave is heating. With no power at all, check the breaker or fuse.
Schedule a diagnostic for your model, carried out at the appliance.
Office details, plus the access notes to pass along.