Read the whole display
Give the code with spaces as shown (F7 E9 reads as F7E9), whether the fan is running, and the model number.
Model-specific code library
Fourteen messages are decoded for the JennAir over-the-range microwave, from keypad SE and sensor E-codes to F-code heating and fan entries, the DOOR message and Demo mode. Many of them end in a breaker reset.
Demo is a practice mode, not a failure. If dOn or dOff just appeared, demo mode was switched on or off. To toggle it, open the door, hold keypad 3 for five seconds until the d icon lights, then press Start within five seconds.
Read the Demo checks14 researched microwave codes. Each model reads codes its own way, so go by your own manual.
Demo is a practice mode, not a failure. If dOn or dOff just appeared, demo mode was switched on or off. To toggle it, open the door, hold keypad 3 for five seconds until the d icon lights, then press Start within five seconds.
Information onlyDOOR (or OPEN/CLOSE DOOR) means the door has stayed closed for five minutes or more without the microwave being started. This prevents unintended starting. Open and close the door, then start the cycle.
Owner checks firstWith E03 the control board received a problem report from the keypad, which JennAir also calls the user interface. The keypad or its wiring may be the cause. Turn off the breaker that serves the microwave, leave it a full minute, then switch it back on and see whether E03 returns.
Reset, then bookWith E11 the control board received a problem report from the gas sensor. The sensor or its wiring may be the cause. Shut off the microwave breaker for a minute, switch it back on and see whether E11 comes back.
Reset, then bookWith E21 the control board found the thermal sensor circuit open. JennAir lists the sensor, the board or the wiring between them. Switch the microwave breaker off for a minute and back on.
Reset, then bookWith E23 the oven failed to reach preheat temperature in thirty minutes. JennAir lists the heater, the board that drives it, or the wiring. Turn the microwave breaker off for a minute, then on.
Reset, then bookWith E24 the cavity registered an overheat reading of 500 F (260 C). JennAir lists the thermal sensor, the gas sensor, the board or the wiring. Turn the microwave breaker off for a minute and on again.
Reset, then bookF2H1 points at the switch that runs the vent fan and light, found on the lower left front side panel, or at its wiring. Turn the microwave breaker off for a minute, then on.
Reset, then bookF3H1 says there may be a problem with the humidity sensor or the associated wiring. Turn the microwave breaker off for a minute, switch it back on, and keep the oven in view for the next minute.
Reset, then bookF3T3 points at the thermistor that reads hood temperature, or at its wiring. Shut off the microwave breaker for a minute, switch it on, and keep the oven in view for a minute.
Reset, then bookF3T4 says there may be a problem with the magnetron temperature thermistor or the associated wiring. Turn off the microwave breaker for a minute, turn it on, and keep the oven in view for a minute.
Reset, then bookF7E9 asks whether the vent is blocked. The upper vent door must open and close freely; trim, cabinetry or something else in the way could let the microwave overheat. Clear it, then turn the breaker off for a minute and back on.
Check, then resetWith F9Q1 the oven could not carry out a function. JennAir names the touch pad, also called the user interface, or its wiring. Turn the microwave breaker off for a minute, turn it on, and keep the oven in view for a minute.
Reset, then bookSE points at the keypad, also called the user interface, or at its wiring. Turn the microwave breaker off for a minute, turn it on, and keep the microwave oven in view for a minute.
Reset, then book
Fourteen messages are decoded for the JennAir over-the-range microwave, from keypad SE and sensor E-codes to F-code heating and fan entries, the DOOR message and Demo mode. Many of them end in a breaker reset.
Every page is the over-the-range microwave. Built-in and countertop JennAir microwaves are not in the pages we read.
Give the code with spaces as shown (F7 E9 reads as F7E9), whether the fan is running, and the model number.
Switch off the breaker before a reset, and never run the microwave empty. Leave the cabinet and the latches to a technician.
First confirm the controls: enter Cook Time, then Cook Power if it is not 100%, and press Start. Then test with one cup of water for one minute on HI. If heat rise is detected, the microwave is heating. With no power at all, check the breaker or fuse.
A microwave that has power but will not start is usually blocked by the door, the Control Lock, Demo Mode or a blank Energy Save display. Confirm that nothing stops the door shutting, check the lock, then switch the breaker off for a minute.
Go by the instructions for your own model. See how we research these pages.
Every page is the over-the-range microwave. Built-in and countertop JennAir microwaves are not in the pages we read.
Take a clear photo of the whole microwave display and of the model label. Add what the appliance was doing when the message came up, and do not borrow the explanation for a different appliance.
An old search phrase is no substitute for manufacturer evidence. When our microwave documents leave a message undecoded, we show the name only and send you toward help, with no part or cause attached.
Browse the manufacturer documents in this microwave library and hold the models on their covers up against your label. Another model needs instructions of its own.